PNA3623P Vector Network Analyzer Full frequency scan, list scan and point frequency measurement available. Capable for transmission measurement (measurement of amplitude vs. frequency characteristics, insertion loss, phase shift, amplifier gain, antenna gain, group delay, antenna azimuth pattern optional), reflection measurement (measure SWR, R.L., complex impedance, reflection phase, electrical length, and Smith Chart display function), time domain fault location function (TDR). Transmission measurement has either logarithm-amplitude display or amplitude-phase display; Reflection measurement has LOG display, SWR display, and Smith Chart display. 5.0” liquid colour display (LCD), serial port output, USB storage disk. Portable(light weight, volume small, option built-in lithium battery power supply satiable for RF measurement under special environment). Application scope and relational properties: l Widely used in the antenna-feed system test and measure installations of FM, TV, CATV, communications, RADAR etc, and also for the RF microwave education laboratory in the university. l Optional matched, for 50Ω, 75Ω, 100Ωetc, different characteristic impedance systems. l Time domain fault location function. It is able to locate a fault in a coaxial cable, with its range: 0-1200 meter,precisely located, a thousandth of full scale l Configure the corresponding test accessories (impedance converter and differential bridge…) so as to satisfy the coaxial cable, twin-twist cable, coaxial connector, etc ,the characteristic impedance of transmission lines, loss, delay, phase shift parameters such as test, and is able to detect leakage of RF cables and shield performance. l Select and prepare corresponding probes capability for the ε measure of such material as the liquids, plane solids, powder, fabric etc. l When a battery power is built in, it is profitable to high climbing, space narrow, inadmissible or no AC 220V field application. Main Specifications | Model | PNA3623P | Signal source | Frequency range | 30~3200MHz | Frequency precision | ≤10-5 | Frequency resolution | 0.025MHz | Display | Insertion loss resolution uncertainty | 0.01dB/div ± 0.2dB ±4%dB value within 50dB range | Reflection resolution uncertainty | 0.002. Small reflection uncertainty is about 0.01(i.e. residual SWR 1.02) | Phase resolution uncertainty | 0.1°. Uncertainty about 5°/amplitude | Characteristic of measurement | Frequency range | 30~3200MHz | Group time delay | 1ns-40μs | Time domain fault location | 0~1200m with 7 scale | Dynamic range | Insertion | 70dB | RL | 50dB | Gain | -20-30dB | Enabled directivity of reflection bridge | ≥40dB | R.L. Load | ≥40dB | Test channel | N-Type(both test channel) | Other | Power Supply | 50Hz AC,220V,0.2A, fuse 1A | Overall dimensions(mm) | 150L×320W×133H | Weight | 5 kg | Standard accessories | 50Ω N-Type test accessories | Options accessories | 75Ω N-Type test accessories, twin-wire system measuring kit, SW anti-interference bridge test accessories, TV, FM anti-interference bridge,SMA-Type test accessories, Built-in Li-ion battery. |
|